Bridgman-type of high pressure cell



Transport Measurements:

1.) Electrical resistivity

Phyrophilte ring (outer diam. 3.4 mm, diam. of sample chamber 2.0 mm) with steatite (white sheet) and on top two samples. They are brigded by a Pb-wire, which serves as pressure gauge.

zelle ohne draht zelle mit draht
 
Fig.1:2 samples (vertical) and a Pb-wire (horizontal)                           Fig.2: Au-wires are attached to the samples and
                                                                                                                    Pb-strip across the gasket.
 
 
  large cell
                                                                     Fig3.: Similar arrangement as in Fig.2

2.) Thermoelectrical power

A figure with the set-up and a short description can be found in the recent paper.
 
 
 
 

3.) ac-calorimetry

 
 

More details about electrical resistivity and thermoelectrcial power can be found in the article by D. Jaccard et al., Rev. High Pressure Sci. Technol. 7, 412-418 (1998) or in the pdf-file Jaccard98.pdf.
A short description about the ac-calorimetry can be found in the article by F. Bouquet et al., Solid State Commun. 113, 367-371 (2000)
and by H. Wilhelm,  see also papers about CePd2Ge2

page still in progress